Fluke 1503 Insulation Tester

The Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.

What is a Megger insulation tester?

The Megger insulation tester is a small, portable instrument that gives you a direct reading of insulation resistance in ohms or megohms. For good insulation, the resistance usually reads in the megohm range.

How Megger is used for open circuit test?

While performing the open circuit test of an installation, it is completely isolated from the supply, the test leads of megger are connected to the circuit under test, the handle is rotated. If megger shows the zero value or some value of resistance, it means the circuit is Correct.

How do I choose an insulation tester?

Make sure you choose an insulation resistance tester that will supply the needed output test voltage. Not all insulation resistance testers are the same: some will supply only up to 1,000 V dc, while others may supply 5,000 V dc test voltage or more.

How do you test for insulation resistance?

High reading that these circuits are not connected. Together the smallest acceptable value of

What is the difference between insulation tester and megger?

An insulation tester performs the basic measuring function a megohmmeter does—measuring very high resistance values by sending a high voltage signal into the object being tested—and it often does much more; it usually performs more functions, including more complex testing and recording of measurements.

What is the minimum acceptable value of insulation resistance?

The rule states that insulation resistance should be approximately one megohm for each 1000 volts of operating voltage, with a one megohm minimum. (By following this rule, a motor rated at 2400 volts should have a minimum insulation resistance of 2.4 megohms).

How do you test insulation resistance with a megger?

How to Use a Megohmmeter

  1. Cut power. Make sure you eliminate any voltage running through the wires you want to test.
  2. Uninstall wires. Disconnect the wires you want to test from both ends of the circuit and all feeding wires in motors.
  3. Connect the ground lead.
  4. Connect to conductor. ...
  5. Build voltage. ...
  6. Read meter. ...
  7. Complete testing.

How do you test wire with a megger?

So what we're gonna be doing is putting some voltage through the wire. And then. We're gonna put one

How many types of megger are there?

There are two types of meggers, manual and electrical megger. The main concept of megger is to measure insulation resistance and machine windings.

How do you megger electrical wires?

Clamp the alligator clip on one of the megger probes to the wire or cable, touch the other probe to the exposed conductor and press the test button. The megger will generate a current between the probes, and the meter will record the resistance of the jacket to the flow of the current.

Can you test insulation resistance with a multimeter?

You use your insulation multimeter to check the insulation resistance of each conductor to ground and of each conductor to the other two.

Which Megger is better for testing installation?

Working Principle of Megger Test 500 Volt DC is sufficient for performing test on equipment range up to 440 Volts. 1000 V to 5000 V is used for testing for high voltage electrical systems.

Why multimeter is not used for measurement of insulation resistance?

An insulation resistance meter can measure into the gigohm or hundreds of gigohm range; some models reach into tera-ohms! The reason a multimeter cannot measure such extremely high resistance is because the measurement is performed with a low voltage (often a 9V battery inside the multimeter).

How do you use a Fluke insulation test?

So we rotate our selector knob to a thousand volts. And uh we select our test in this case. I'm

What is an acceptable IR reading?

By reference to Table 61 of BS 7671, Regulation 612.3. 2 indicates that the minimum acceptable value of insulation resistance for a distribution circuit with a distribution board or consumer unit and all its final circuits connected is 1 MΩ.

What is the minimum acceptable reading for insulation resistance on a 230v circuit?

Test voltage 500v for 230v or 400v installations or circuits with a minimum insulation resistance of 1 M ohm (1000,000 ohms).

Does cable length affect insulation resistance?

Long run lengths: Longer cable runs have lower resistance because there is a large conductive area. The tester measures the insulation resistance by measuring the leakage through the insulation. Longer runs will result in lower insulation resistance values.

Why DC voltage is used for insulation testing?

If we apply DC voltage then as we know Capacitor blocks the flow of DC, only leakage current due to imperfection of insulator will flow and hence the Resistance measured by Megger will actually represent Insulation Resistance. This is the reason, an Insulation Tester or Megger have DC voltage generator.

What is acceptable value for Megger?

Max.Voltage Rating Of EquipmentMegger SizeMin.IR Value
600 Volts1,000 Volts100 MΩ
5 KV2,500 Volts1,000 MΩ
8 KV2,500 Volts2,000 MΩ
15 KV2,500 Volts5,000 MΩ